package sandbox
import "syscall"
const (
SUID_DUMP_DISABLE = iota
SUID_DUMP_USER
)
func SetDumpable(dumpable uintptr) error {
// linux/sched/coredump.h
if _, _, errno := syscall.RawSyscall(syscall.SYS_PRCTL, syscall.PR_SET_DUMPABLE, dumpable, 0); errno != 0 {
return errno
}
return nil
}
func SetPdeathsig(sig syscall.Signal) error {
if _, _, errno := syscall.RawSyscall(syscall.SYS_PRCTL, syscall.PR_SET_PDEATHSIG, uintptr(sig), 0); errno != 0 {
return errno
}
return nil
}
// IgnoringEINTR makes a function call and repeats it if it returns an
// EINTR error. This appears to be required even though we install all
// signal handlers with SA_RESTART: see #22838, #38033, #38836, #40846.
// Also #20400 and #36644 are issues in which a signal handler is
// installed without setting SA_RESTART. None of these are the common case,
// but there are enough of them that it seems that we can't avoid
// an EINTR loop.
func IgnoringEINTR(fn func() error) error {
for {
err := fn()
if err != syscall.EINTR {
return err
}
}
}